Loading…

Loading grant details…

Active HORIZON European Commission

DYnamically MANaged self-cooling HPC Data Centers

€4M EUR

Funder European Commission
Recipient Organization Idp Ingenieria Y Arquitectura Iberia Sl
Country Spain
Start Date Jul 01, 2024
End Date Jun 30, 2027
Duration 1,094 days
Number of Grantees 10
Roles Participant; Coordinator
Data Source European Commission
Grant ID 101161930
Grant Description

DYMAN targets the development of a completely new design of adsorption chillers based on the following innovations (1) New low-temperature adsorbents achieving high capacities at very low driving temperatures below 50 C. (2) New type of adsorption heat exchangers made of 3D printed structures integrating the adsorption material into a porous structure, which reduces the internal thermal resistances and improvement of heat transfer by two-phase flow, enhancing the heat transfer rate and reducing the internal electricity consumption of the unit.

Additionally the project aims to develop at second core concept to further develop an existing two-phase cooling system, for high-performance computing servers to handle thermal loads more efficiently from next-generation processors.

Goals include increasing cooling capacities for processors generating high heat fluxes like the Nvidia H100 chip which produces 70 W/cm2.

An additional objective is to recover 50% of waste heat from processors to generate additional cooling power through a sorption heat pump.

Combining two-phase cooling directly with heat-powered cooling could significantly improve efficiency over conventional air or water-based cooling methods alone.

The objective here is to 1)further develop the present two-phase cooling system to work in an efficient way in combination with the sorption heat pump (concept 1) 2) Development of new evaporator with new advanced surfaces for high heat transfer coefficients (3) Development of new condenser integrated with the heat adsorber of sorption heat pump.

This is a crucial component that can improve the efficiency of the whole integrated system to recovery up to 50% of rejected heat.

Furthermore, the cooling data center management is a complex engineering system with interactions with different components of the data centers.

So, DYMAN proposes a new way of active management of the data center integrating the cooling system as part of the optimization of processor management

All Grantees

Building Digital Twin Association; Comet Global Innovation, Sl; in Quattro Srl; Idp Ingenieria Y Arquitectura Iberia Sl; Universita Degli Studi Di Torino; Consiglio Nazionale Delle Ricerche; Sorption Technologies Gmbh; Energy Aware Solutions Sl; Cibelios Ingenieria Sl; Barcelona Supercomputing Center Centro Nacional de Supercomputacion

Advertisement
Discover thousands of grant opportunities
Advertisement
Browse Grants on GrantFunds
Interested in applying for this grant?

Complete our application form to express your interest and we'll guide you through the process.

Apply for This Grant